Re: Error collecting performance data: NT_STATUS_IO_TIMEOUT
I recently was able to locate that only one server is unable to poll the request from the zenoss, i enabled all ports, i removed and re added the server again and again..changed the device...
View Articlelocalhost Unhandled exception in zenhub service
I have been receiving a number of alerts on Zenoss, i have no idea as to how and why, i am basically a windows admin , and have little bit expertise on Zenoss, however i have set it by mself in our...
View ArticleZenoss 4.2.3 alerts reading in bytes would like to have email alerts in...
I am still very new to Zenoss and I am having trouble with output emails for example: Event: 'threshold of high utilization exceeded: current value 110168460.901864' At: 2014/02/10 09:16:25.000...
View ArticleZencommand is showing missed runs
Hi, On a few of my collectors zencommand is showing a bunch of missed runs. I cannot seem to find any documentation on this. 2014-02-11 09:12:26,120 INFO zen.zencommand: 427 devices processed (187457...
View ArticleEvent Notifications - modifying email text
I'd like to tweak the email content when an Event Trigger is activated. Here's what I have now: Device: ${eventSummary/actor/element_title} Component: ${evt/component} Severity: ${evt/severity} Time:...
View ArticleCopying zenoss content from one zenoss 424 server to another zenoss 424 server.
So here is my dilemma and here is what i'm working with. So we currently have Zenoss 3.2.1 in production running RHEL version 5. My project is to create a new vm with RHEL version 6, install zenoss...
View ArticleRe: Migrating devices & template from one server to another
I just saw this and it's quite old. Did you ever get a fix for this ?
View ArticleZenoss Modeling restarting Cisco Wireless AP
Hi, I have an issue with Zenoss Core 4.2.0 . When I add a Cisco Aironet 2602E AP to the devices and Zenoss models the devices, the device restarts. This unfortunately does not only happen on the...
View ArticleAbout the job PENDING
Hi all, the problem is as the title. When I add the device from the web UI, the state of the job is alway PENDING. At last, I restart the zenoss daemons. Why does not the job's state change from...
View ArticleUnable to view component for HRSWInstalledMap on ZenOSS UI after modeling.
After modeling device for HRSWInstalledMap modeler, I am able to get data for the device which consist of Product key and installed date in the backend.But I am unable to see component for...
View Article"Model Time" significance when running modelers
Kindly help me to get the details of the below queries : (1) What does "Model time" mean ? 1> Is it the time when device modelling was initiated or 2> When device was...
View ArticleRe: Infrastructure in tact however no events appearing
Errors in the winperf log: 2014-02-18 05:05:31,397 WARNING zen.winperf.PerfRpc: Bad counter for device 172.20.75.201: \LogicalDisk(\\?\Volume{f4f1740e-c7c4-11df-9dbf-806e6f6e6963})\% Disk Write Time...
View ArticleMoving Zenoss to a new server
Recently I have installed zenoss on a new server and would like to take the backup of my current zenoss instance and load it on to the new instance. Both the new and the old server are centos 6 servers...
View ArticleEmail Allerts issues Zenoss core 4.2.4
Hi all, having issues with setting email alerts. looks like i cant get email alerts to more than one "notifications" if set up a few triggers and set them up with email notifications. - this works......
View ArticleMonitoring OID without graphing
Hello All, I'm new to Zenoss and SNMP monitoring, so bare with me . I have a couple of APC UPS's that I would like to monitor an OID that shows the battery output status. I'm having a hard time trying...
View ArticleRe: Monitoring OID without graphing
Please use the new forums athttp://www.zenoss.org/forums/community-zenoss-support
View ArticleQuestion in the way a graph displays
I am sorry if this is easly found somewhere. In the below graph does the k mean kilo and m mean milli? Or am I off on that thinking. Thanks for your help, Keith
View ArticleZenoss and DNS lookups
Hi, I've had serveral issues caused by the fact that Zenoss doesn't automatically refresh DNS and IPs on hosts. I know I can do it manually via "Actions" -> "Reset IP". I know how to do this via...
View ArticleTrigger bug!
Hi, I have ZenOSS 4.2.4 installed on CentOS 6.5 x64. I found 2 bugs (i think), hope it is not a bug and you can help me fix it: After creting a trigger I double click on the trriger or clicking the...
View ArticleFindPosKeyError script issue
Over the last couple weeks, I've had a number of devices coming up with POSKeyError messages. I discovered the "FindPosKeyError.py" script that was available on...
View Article